Miguel Couceiro
Investigador ( LIP Coimbra )
Grupos
Scatter Fraction, Count Rates, and Noise Equivalent Count Rate of an RPC TOF-PET System: Simulation Study Following the NEMA NU2-2001 Standards
- Autor(es): Couceiro, M.; Crespo, P. ; Marques, R.F. ; Fonte, P.
-
Publicação: 2014-05-11
-
Referência: IEEE Trans. Nucl. Sci.61 (2014) 1153-1163
Resistive plate chambers in positron emission tomography
- Autor(es): Paulo Crespo, Alberto Blanco, Miguel Couceiro, Nuno C. Ferreira, Luís Lopes, Paulo Martins, Rui Ferreira Marques, Paulo Fonte
-
Publicação: 2013-07-01
-
Referência: The European Physical Journal Plus (2013) 128:73
On Lesion Detectability by Means of 300ps-FWHM TOF Whole-Body RPC-PET: an Experiment-Based Simulation Study
- Autor(es): P. Martins, M. Couceiro, N. C. Ferreira, R. Ferreira Marques, P. Fonte, L. Mendes, P. Crespo
-
Publicação: 2012-12-31
-
Referência: 2012 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) (2012) 2440 - 2444
Scatter Fraction, Count Rates, and Noise Equivalent Count Rate of an RPC TOF-PET System: Simulation Study Following the NEMA NU2-2001 Standards
- Autor(es): M. Couceiro, P. Crespo, R. F. Marques and P. Fonte
-
Publicação: 2012-12-31
-
Referência: 2012 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) (2012) 2651 - 2660
Whole-body single-bed time-of-flight RPC-PET: simulation of axial and planar sensitivities with NEMA and anthropomorphic phantoms
- Autor(es): P. Crespo, J. Reis, M. Couceiro, A. Blanco, N. C. Ferreira, R. Ferreira Marques, P. Fonte
-
Publicação: 2012-06-12
-
Referência: IEEE Trans. Nucl. Sci. 59 (2012) 520
Spatial resolution of human RPC-PET system
- Autor(es): M. Couceiro, P. Crespo, L. Mendes, N. Ferreira, R. Ferreira Marques and P. Fonte
-
Aceitação: 2010-08-04 Publicação: 2012-01-01
-
Referência: Nucl. Instrum. and Meth. in Phys. Res. A 661 (2012) S156-S158
A Direct Time-of-Flight Reconstruction for Whole-Body Single-Bed RPC-PET: Results from Lesion and Anthropomorphic Simulated Data
- Autor(es): P. Martins, A. Blanco, F. Caramelo, M. Couceiro, N. C. Ferreira, R. Ferreira Marques, P. Fonte, L. Mendes, P. Crespo
-
Publicação: 2011-10-23
-
Referência: 2011 IEEE Nuclear Science Symposium Conference Record MIC9.S-217
Whole-body single-bed time-of-flight RPC-PET: simulation of axial and planar sensitivities with NEMA and anthropomorphic phantoms
- Autor(es): P. Crespo, J. Reis, M. Couceiro, A. Blanco, N. C. Ferreira, R. Ferreira Marques, P. Fonte
-
Aceitação: 2009-12-31 Publicação: 2010-01-29
-
Referência: 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC), pp. 3420 - 3425
Efficiency of RPC detectors for whole-body human TOF-PET
- Autor(es): A. Blanco, M. Couceiro, P. Crespo, N. C. Ferreira, R. Ferreira Marques, P. Fonte, L. Lopes, J. A. Neves
-
Aceitação: 2008-11-01 Publicação: 2009-05-01
-
Referência: Nucl. Instrum. and Meth. in Phys. Res. A 602 (2009) 780-783
RPC-PET: status and perspectives
- Autor(es): M. Couceiro, A. Blanco, Nuno C. Ferreira, R. Ferreira Marques, P. Fonte, L.Lopes
-
Aceitação: 2007-10-01 Publicação: 2007-10-01
-
Referência: Nucl. Instrum. and Meth. in Phys. Res. A 580 (2007) 915-918
Sensitivity assessment of wide axial FOV PET systems via Monte Carlo simulations of NEMA–like measurements
- Autor(es): M. Couceiro, N. C. Ferreira, P. Fonte
-
Aceitação: 2007-09-21 Publicação: 2007-09-21
-
Referência: Nucl. Instrum. and Meth. in Phys. Res. A 580 (2007) 485-488